Setup Menu 
 
 
97 
 
CI 
Menu  Item 
Description 
Parameters 
PE 
Select  the Program  Entry (PE)  to 
configure  the decryption  settings. 
PE1 to  PE32 
Decrypt 
Determines  whether  to decrypt  the 
channel  or to  specify  the specific 
components  to  decrypt. 
ON (default)  - Decrypts  the 
entire program  entry. 
OFF - Disables  decryption  for 
the current  program  entry. 
Comp  - Allows  specific 
components  to  be decrypted,  as 
specified  in the component  list. 
Note: If  the CI Slot  is set to 
Auto  for  PE1, then Decrypt  can 
only be set to  ON. 
CI Slot 
Select  the CAM  slot  to  use for 
decryption. 
TOP, BOTTOM,  AUTO 
AUTO - PE1  only. The software 
automatically  assigns  the slot 
capable  of decrypting  the 
stream.  If CI  Slot  is set to 
AUTO, Decrypt  must  be set to 
ON. 
TOP -  The top CAM  slot  is used 
for  decryption. 
BOTTOM  - The bottom  CAM 
slot  is used  for  decryption. 
COMP  only 
If  any program  entries  have selected  Comp  for  the Decrypt 
parameter,  you can customize  the PID or  stream  type to decrypt  the 
program. 
To  Add a Record,  press  the ADV button,  select  Insert  and define  the 
appropriate  parameters.   
To  delete an existing  record,  select  Delete and confirm  your deletion.  
There are three different  methods  in setting  a customized  record: 
PID -  Set Mode to  PID and  enter PID  number. 
Stream  Type - Set Mode  to  STREAM,  select  a Stream  type (audio, 
video, subtitle,  ttx, or user)  and enter  Inst  (instance)  of  the stream 
type. There is an additional  configuration  if you select  user  as the 
Stream  type (see below). 
Stream  Type: User - Set Mode  to STREAM,  Stream  type to  USER, 
manually enter  the stream code  in Type, and then the Inst  (instance) 
of  the stream  type.