Cisco Cisco D9824 Advanced Multi Decryption Receiver Guida All'Installazione
Chapter 4 Front Panel Operation
120
Parameter
Description
RST
Pass
TOT
Pass
DIT
Pass
SIT
Pass
ECM
Drop
EMM
Drop
DRT
Drop
CDT
Drop
10 Press MENU three times to exit the TS Out menu and save the data. If the
changes cannot be saved/made, a message will be displayed indicating "Bad
configuration data". The following options are available: Abandon, Exit or
Return. Select Return to re-enter the parameter.
Note: When remapping an input program channel to an output channel, ensure
that the PIDs are mapped to different PIDs to avoid PID collisions.
configuration data". The following options are available: Abandon, Exit or
Return. Select Return to re-enter the parameter.
Note: When remapping an input program channel to an output channel, ensure
that the PIDs are mapped to different PIDs to avoid PID collisions.
Sy nchronizing Output Serv ices
To synchronize the output to the input Services Only:
This operation synchronizes the inputs to the outputs according to the service
assignments only. This is useful when you already have PID assignments set for the
services but want to ensure that the services are mapped correctly.
1 On the DPM menu, map the output services as desired.
2 Select PE Resync: Svcs. The receiver will synchronize the PE output according to
assignments only. This is useful when you already have PID assignments set for the
services but want to ensure that the services are mapped correctly.
1 On the DPM menu, map the output services as desired.
2 Select PE Resync: Svcs. The receiver will synchronize the PE output according to
the available input services only, and ignore the input to output service PID
mapping.
mapping.
To synchronize the output to the input PIDs only:
This operation synchronizes the inputs to the outputs according to the PID
assignments only. This is useful when you have already have the services set up but
want to synchronize to the incoming PIDs.
1 On the DPM menu, map the output services as desired.
2 Select PE Resync: PIDs. The receiver will synchronize the PE output according to
assignments only. This is useful when you have already have the services set up but
want to synchronize to the incoming PIDs.
1 On the DPM menu, map the output services as desired.
2 Select PE Resync: PIDs. The receiver will synchronize the PE output according to
the input PIDs only, and ignore the service assignment categories/names.
To synchronize the output to All (Services and PIDs):
This operation synchronizes the inputs to the outputs of the current PMT according
to the service assignments and then the PID assignments. This is similar to a sample
and hold function.
1 On the Detailed Program Mapping Active menu, map the outputs services as
to the service assignments and then the PID assignments. This is similar to a sample
and hold function.
1 On the Detailed Program Mapping Active menu, map the outputs services as
desired.