Cisco Cisco ONS 15600 SDH Multiservice Provisioning Platform (MSPP) Riferimenti tecnici
22
•
LOCATION is the location where the operation is to be carried out.
•
LPBKTYPE is a loopback type and is optional. LPBKTYPE can be FACILITY or TERMINAL.
Input Example:
RLS-LPBK-T1::FAC-17-2:34::,,,FACILITY;
Log Out of TL1
When you are finished using TL1, you must log out of the session. Logging out of TL1 only has to be
done once per session.
done once per session.
Step 1
If you logged into TL1 via CTC, you must log out by pressing the Disconnect button or by
issuing the CANC-USER command as shown in the following steps.
issuing the CANC-USER command as shown in the following steps.
If you logged into TL1 via Telnet or craft interface, you must log out by issuing the
CANC-USER command.
CANC-USER command.
Input Format:
CANC-USER:[<TID>]:<USERID>:<CTAG>;
•
TID is the name of the node you want to access. If you only want to query the node you
connected to leave the TID blank.
connected to leave the TID blank.
•
USERID is your user ID. Maximum of 10 alphanumeric characters.
•
CTAG is any non-blank character series that does not have to be unique.
Input Example:
CANC-USER:PETALUMA:DXT:100;
Step 2
Confirm you receive a COMPLD response to indicate the command was completed
successfully.
successfully.
Response Example:
TID001 03-07-22 02:45:12
M 100 COMPLD
;
Obtaining Optical Networking Information
This section contains information that is specific to optical networking products. For information that
pertains to all of Cisco, refer to the
pertains to all of Cisco, refer to the