Cisco Cisco HDT Network Storage Hard Drive Trays Guida Dell'Amministratore

Pagina di 190
Troubleshooting
Repairing a Degraded Array
Linksys Small Business NSS4000 and NSS6000 Series Network Storage System Administration Guide
159
A
NOTE
When adding disks to an array, we recommend you use the same model of disk with 
the same capacity. The new disk must have at least the same capacity of the 
smallest disk currently in the array. With the exception of a JBOD, RAIDs are 
configured to use the maximum of the smallest disk capacity in the array for each 
additional disk in the array. For example, if you install two, 250 GB disks and one 500 
GB disk, the total capacity is 750 GB.
To add a disk to a degraded array:
STEP 1
If you are replacing a disk, remove the failed drive from the NSS and install the 
replacement disk. 
STEP 2
From the Manager Menu, click Storage 
   
RAID.  
The RAID page appears.
STEP 3
In the RAID Arrays table, click Edit for the applicable RAID array.