Cisco Cisco Agent Desktop 8.0 Guida Alla Risoluzione Dei Problemi
However, after this the CAD Desktop Administrator (CDA) sync did not work and the reason was due to this
error seen in the AW server.
error seen in the AW server.
Log Name: Application
Source: MSSQLSERVER
Date: 7/15/2012 1:38:33 PM
Event ID: 18456
Task Category: Logon
Level: Information
Keywords: Classic,Audit Failure
User: ADMINWORK\CADUser
Computer: XXXXXXXXX
Description
Login failed for user 'ADMINWORK\CADUser'. Reason: Token−based server access validation failed with
an infrastructure error. Check for previous errors. [CLIENT: X.X.X.X]
an infrastructure error. Check for previous errors. [CLIENT: X.X.X.X]
Solution
On the AW server through Microsoft SQL Server Management Studio, add the "CADUser" in the Login
Properties pane and check the public and sysadmin check boxes.