Cisco Cisco Prisma II EDR Receiver Guida All'Installazione

Pagina di 178
 
 
 
Troubleshooting Alarm Conditions 
 
 
133 
 
Alarm 
Function 
Possible Causes 
Possible Solutions 
PsOk 
Bus voltage 
status 
 
Power supply failure 
 
Check power supply 
Communication 
Status 
Status of LCI 
communication 
with module 
(also indicated 
by negative poll 
count) 
 
LCI cable 
disconnected 
 
Receiver module 
failure 
 
PC serial port not 
operating correctly 
 
Check LCI cable 
 
Replace receiver 
module 
 
Reconfigure PC serial 
port 
Rx1_LOS 
Loss of signal 
for Rx1 
 
Broken fiber 
 
Transmitter failure 
 
Faulty OPM 
 
Low input power 
 
Alarm limits set 
incorrectly 
 
Check, clean fiber 
 
Check transmitter 
 
Replace faulty OPM 
Rx2_LOS 
Loss of signal 
for Rx2 
 
Broken fiber 
 
Transmitter failure 
 
Faulty OPM 
 
Low input power 
 
Alarm limits set 
incorrectly 
 
Check, clean fiber 
 
Check transmitter 
 
Replace faulty OPM 
Rx3_LOS 
Loss of signal 
for Rx3 
 
Broken fiber 
 
Transmitter failure 
 
Faulty OPM 
 
Low input power 
 
Alarm limits set 
incorrectly 
 
Check, clean fiber 
 
Check transmitter 
 
Replace faulty OPM 
Rx4_LOS 
Loss of signal 
for Rx4 
 
Broken fiber 
 
Transmitter failure 
 
Faulty OPM 
 
Low input power 
 
Alarm limits set 
incorrectly 
 
Check, clean fiber 
 
Check transmitter 
 
Replace faulty OPM