Cisco Cisco Tunnel Terminating Gateway (TTG)
Exec Mode Commands (D-S)
▀ gtpp storage-server streaming start
▄ Command Line Interface Reference, StarOS Release 18
4108
gtpp storage-server streaming start
This command enables to start streaming of the copied CDR files from active chassis when the ICSR switchover occurs.
Important:
This command is obsolete in release 16.0. In 16.0 and later releases, use the “
gtpp push-to-
active url
” CLI command in global configuration mode to enable the automatic transfer of stranded CDRs to active
chassis.
Product
GGSN
P-GW
S-GW
SGSN
Privilege
Security Administrator, Administrator, Operator
Mode
Exec
The following prompt is displayed in the Exec mode:
[local]host_name#
Syntax
gtpp storage-server streaming start [ group name group_name ]
group name group_name
Specifies the name of a GTPP group configured in the current context as an alphanumeric string of 1 through
63 characters.
Note that, if the group name is not specified, then all the GTPP groups in the current context will be
considered. If the group name is specified, then only the group provided in this CLI command will be
considered.
63 characters.
Note that, if the group name is not specified, then all the GTPP groups in the current context will be
considered. If the group name is specified, then only the group provided in this CLI command will be
considered.
Usage
This command is used to resynchronize the CDRs left on local HDD with the active GTPP' streaming feed to
transfer the CDRs from active chassis to IT mediation device during ICSR switchover.
Note that this CLI command must be executed from within the context in which the GTPP Storage Server is
configured.
In the event of ICSR switchover, to transfer the copied CDRs from active chassis to IT mediation device,
follows these steps:
transfer the CDRs from active chassis to IT mediation device during ICSR switchover.
Note that this CLI command must be executed from within the context in which the GTPP Storage Server is
configured.
In the event of ICSR switchover, to transfer the copied CDRs from active chassis to IT mediation device,
follows these steps:
1. Manually copy files from old active chassis to new active chassis.
2. Issue this CLI command “
gtpp storage-server streaming start
” to start streaming of the
copied files from active chassis.
3. If the streaming is in progress, then wait till the current file is fully streamed out. After the current
file is fully streamed out, then rebuild the file list (to get the copied CDR files) and start streaming
based on the timestamp.
based on the timestamp.