Cisco TelePresence MX700 and MX800
Administrator Guide
Standard COM-port 
(9-pin, female)
Remove the left side 
cover to get access to 
the connectors.
Computer
Video 
system
USB
COM 
(9-pin, male)
COM 
(9-pin, male)
COM 
(9-pin, female)
RS-232 adapter
Serial cable
Serial interface (RS-232)
MX700 and MX800 have a standard COM-port for serial 
communication. Connect a standard 9-pin RS-232 serial cable 
to the COM-port. If the computer does not have a standard serial 
connector, you need an RS-232 adapter on the computer side.
The serial connection can be used without an IP-address, DNS, or 
a network.
Parameters:
•  Baud rate: Configurable. Default 115200 bps
•  Data bits: 8
•  Parity: None
•  Stop bit: 1
Video system settings
Serial communication is enabled by default. Use the following 
configuration to change the behavior:
SerialPort > Mode
For security reasons, you are asked to sign in before using the 
serial interface. Use the following setting to change the behavior:
SerialPort > LoginRequired
We recommend using the default baud rate because the video 
system may give much feedback. Use the following setting if you 
want to adjust the baud rate.
SerialPort > BaudRate
Restart the video system when you have made changes to the 
serial port settings.