Cisco Cisco TelePresence MX700

Pagina di 70
New feature and functionality descriptions CE8.3.0 
 
21
 
Spark on-boarding with LAN paired Touch 10 
It is no longer required that the Touch 10 is directly paired to the video endpoint to offer Spark as an 
activation alternative. While the system is in factory reset state and displaying the “Welcome” screen, 
pair the Touch 10 to the system IP address and follow the steps on the Touch 10.  
This also enables Touch 10 operation for systems previously only supported with the TRC 6 remote 
control while activated on Spark, such as the Cisco TelePresence SX10 and SX20. 
The Spark Room System must be running CE8.3.0 from a factory default state in order to on-board to 
Spark with a LAN paired Touch 10. The “Welcome” screen must be visible and the wizard must not be 
completed. Pair the Touch 10 to the Room System while in this state and follow the steps on the 
Touch 10.  
Updated requirements for Spark registration for the below Room Systems (factory default state, 
CE8.3.0):  
Spark Room System  
CE Version 
Touch 10 (Direct) 
Touch 10 (LAN) 
TRC6 
SX10, SX10N  
CE8.3.0 
No 
Yes 
Yes 
SX20, SX20N 
CE8.3.0 
No 
Yes 
Yes 
SX80 
CE8.3.0 
Yes 
Yes 
No 
MX200 G2/MX300 G2 
CE8.3.0 
Yes 
Yes 
No 
MX700/MX800/MX800D 
CE8.3.0 
Yes 
Yes 
No 
DX70/DX80 
CE8.3.0 
N/A (use touch screen)  N/A (use touch screen)  N/A 
 
Power save mode on MX700, MX800 and MX800 Dual 
“Power save” mode is designed to reduce power consumption while the system is not in use over 
time, for example during out of office hours and weekends. The feature is an extension of the normal 
standby mode but is disabled by default. To enable “power save” mode we recommend to configure a 
power save schedule (out of office hours) from the web interface of the video system.  
When the system enters “power save” mode, power supply to the integrated cameras are turned off 
and will save approximately 15 watts per camera while in “power save” mode. The video system will 
automatically wake up from power save mode 5 minutes before it enters the normal office hours and 
use regular standby mode for the configured duration. The power save schedule is available from the 
“Time” configuration and activated by setting “PowerSave” to “OutsideOfficeHours” within the 
“Standby” configuration.