The following physical dimensions apply to the Cisco IronPort M1070 and 670
Security Management appliances:
Security Management appliances:
•
Height: 8.64 cm (3.40 inches)
•
Width: 48.24 cm (18.99 inches) with rails installed (with or without rails)
•
Depth: 72.06 cm (28.40 inches)
•
Weight: maximum 26.76 kg (59 pounds)
The following physical dimensions apply to the Cisco IronPort M160 Security
Management appliance:
Management appliance:
•
Height: 4.20 cm (1.68 inches)
•
Width: 48.26 cm (19.00 inches) with rails installed (without rails 17.5 inches)
•
Depth: 57.60 cm (22.70 inches)
•
Weight: maximum 7.80 kg (21.6 pounds)
Preparing for Setup
To set up the Security Management appliance, you need to use the System Setup
Wizard in the graphical user interface (GUI). The Security Management appliance
does not support system setup through the command line interface (CLI). For
more information about running the wizard, see the
Wizard in the graphical user interface (GUI). The Security Management appliance
does not support system setup through the command line interface (CLI). For
more information about running the wizard, see the
.
Before you can log in to the GUI, you need to set up a private connection between
a PC and the Security Management appliance. For example, you can use the
included crossover cable to connect directly from the Management port on the
appliance to a laptop. Optionally, you can connect through an Ethernet connection
between a PC and the network (for example, an Ethernet hub) and between the
network and the Management port on the Security Management appliance. The
factory assigned IP address of the Management port is 192.168.42.42. After setup,
go to the Management Appliance > Network > IP Interfaces page on the main
Security Management appliance to change the interface that the Security
Management appliance uses.
a PC and the Security Management appliance. For example, you can use the
included crossover cable to connect directly from the Management port on the
appliance to a laptop. Optionally, you can connect through an Ethernet connection
between a PC and the network (for example, an Ethernet hub) and between the
network and the Management port on the Security Management appliance. The
factory assigned IP address of the Management port is 192.168.42.42. After setup,
go to the Management Appliance > Network > IP Interfaces page on the main
Security Management appliance to change the interface that the Security
Management appliance uses.