Cisco Cisco Email Security Appliance C170 Guida Utente

Pagina di 1140
 
3-31
Cisco AsyncOS 8.5.5 for Email Security User Guide
 
Chapter 3      Setup and Installation
  Using the System Setup Wizard
Note
Because the 
systemsetup
 command only configures one listener for both inbound and outbound mail for 
C10/100 customers, all outgoing mail will be calculated in the Mail Flow Monitor feature (which is 
normally used for inbound messages). See 
Do you want to enable rate limiting for this listener? (Rate limiting defines the 
maximum number of recipients per hour you are willing to receive from a remote domain.)  
[Y]> y
Enter the maximum number of recipients per hour to accept from a remote domain.
[]> 450
Default Policy Parameters
==========================
Maximum Message Size: 10M
Maximum Number Of Connections From A Single IP: 50
Maximum Number Of Messages Per Connection: 100
Maximum Number Of Recipients Per Message: 100
Maximum Number Of Recipients Per Hour: 450
Maximum Recipients Per Hour SMTP Response:
    452 Too many recipients received this hour
Use SenderBase for Flow Control:  Yes
Spam Detection Enabled:  Yes
Virus Detection Enabled:  Yes
Allow TLS Connections: No
Would you like to change the default host access policy?  [N]>
Listener MailInterface created.
Defaults have been set for a Public listener.
Use the listenerconfig->EDIT command to customize the listener.
*****