Oregon Scientific BAR208HG Dépliant

Pagina di 2
temperature is out of this range. 
WEATHER TRENDS
The  temperature,  humidity  and  pressure  trend  icons  are 
based on recent sensor readings. 
            RISE 
     STEADY                      FALL
  
  
 
MOON PHASE
In moon phase mode, press 
 or 
  to scan through the 
years (2001 to 2099).
                New Moon   
        Full Moon
               Waxing Crescent 
        Waning Gibbous
               First quarter    
        Last quarter
                Waxing Gibbous                        Waning Crescent
NOTE Star icons around the moon phase will be displayed 
from 6 o’clock in the evening to 6 o’clock the next morning.
BACKLIGHT
Press LIGHT to activate backlight for 5 seconds.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
• 
Do not subject the unit to excessive force, shock, dust, 
temperature or humidity.
• 
Do not cover the ventilation holes with any items such as 
newspapers, curtains etc.
• 
Do not immerse the unit in water. If you spill liquid over it, 
dry it immediately with a soft, lint-free cloth.
• 
Do  not  clean  the  unit  with  abrasive  or  corrosive 
 
materials. 
• 
Do not tamper with the unit’s internal components. This 
invalidates the warranty.
• 
Only  use  fresh  batteries.  Do  not  mix  new  and  old 
 
batteries.
• 
Images shown in this manual may differ from the actual 
display.
• 
When  disposing  of  this  product,  ensure  it  is  collected 
separately for special treatment.
• 
Placement  of  this  product  on  certain  types  of  wood 
may  result  in  damage  to  its  finish  for  which  Oregon 
Scientific  will  not  be  responsible.  Consult  the  furniture 
 
manufacturer’s care instructions for information.
• 
The  contents  of  this  manual  may  not  be  reproduced 
 
without the permission of the manufacturer.
• 
Do  not  dispose  old  batteries  as  unsorted  municipal 
waste.  Collection  of  such  waste  separately  for  special 
treatment is necessary.
• 
Please  note  that  some  units  are  equipped  with  a 
 
battery  safety  strip.  Remove  the  strip  from  the  battery 
 
compartment before first use.
NOTE The technical specifications for this product and the 
contents of the user manual are subject to change without 
notice.
SPECIFICATIONS
TYPE 
DESCRIPTION
MAIN UNIT
L x W x H 
182.5 x 94 x 51 mm  
 
 
(7.19 x 3.70 x 2.01 in)
Weight 
241 g (8.5 oz) 
without battery
Temperature range 
-5°C to 50°C (23°F to 122°F)
Resolution 
0.1°C (0.2°F)
Signal frequency  
433 MHz
Humidity range 
25% - 95%
Humidity resolution 
1%
Power 
3 x UM-3 (AA) 1.5 V batteries
REMOTE UNIT (THGR122NR)
L x W x H 
92 x 60 x 20 mm  
 
 
(3.62 x 2.36 x 0.79 in)
Weight 
63 g (2.22 ounces) without battery
Transmission range 
30 m (98 ft) unobstructed
Temperature range 
-20°C to 60°C (-4°F to 140°F)
Power 
2 x UM-4 (AAA) 1.5 V batteries
ABOUT OREGON SCIENTIFIC
Visit  our  website  (www.oregonscientific.com)  to  learn  more 
about  Oregon  Scientific  products.  If  you’re  in  the  US  and 
would like to contact our Customer Care department directly, 
please visit: www2.oregonscientific.com/service/support 
OR 
Call 1-800-853-8883. 
For international inquiries, please visit: 
www2.oregonscientific.com/about/international
FCC STATEMENT
This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  This 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation.
  WARNING  Changes  or  modifications  not  expressly 
approved by the party responsible for compliance could void 
the user’s authority to operate the equipment.
  NOTE    This  equipment  has  been  tested  and  found  to 
comply with the limits for a Class B digital device, pursuant 
to  Part  15  of  the  FCC  Rules. These  limits  are  designed  to 
provide reasonable protection against harmful interference in a 
residential installation.
This  equipment  generates,  uses  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used  in 
accordance  with  the  instructions,  may  cause  harmful 
interference  to  radio  communications.  However,  there  is 
no guarantee that interference will not occur in a particular 
installation.  If  this  equipment  does  cause  harmful 
interference  to  radio  or  television  reception,  which 
can  be  determined  by  turning  the  equipment  off 
and  on,  the  user  is  encouraged  to  try  to  correct  the 
interference  by  one  or  more  of  the  following  measures:
• 
Reorient or relocate the receiving antenna.
• 
Increase  the  separation  between  the  equipment  and 
 
receiver.
• 
Connect  the  equipment  into  an  outlet  on  a  circuit 
 
different from that to which the receiver is connected.
• 
Consult  the  dealer  or  an  experienced  radio  /  TV 
 
technician for help.
DECLARATION OF CONFORMITY
The  following  information  is  not  to  be  used  as  contact  for 
support or sales. Please call our customer service number 
(listed on our website at www.oregonscientific.com, or on the 
warranty card for this product) for all inquiries instead.
We
Name: 
 
Oregon Scientific, Inc.
Address:   
19861 SW 95
th
 Ave.,Tualatin,
  
 
Oregon 97062 USA
Telephone No.: 
1-800-853-8883
declare that the product 
Product No.: 
BAR208HGA
Product Name: 
Advanced Weather Station  
 
 
with Atomic Time
Manufacturer: 
IDT Technology Limited
Address:   
Block C, 9/F, Kaiser Estate,
       
 
Phase 1,41 Man Yue St.,    
  
 
Hung Hom, Kowloon, 
  
 
Hong Kong
is in conformity with Part 15 of the FCC Rules.  Operation is 
subject to the following two conditions: 1) This device may 
not cause harmful interference. 2) This device must accept 
any  interference  received,  including  interference  that  may 
cause undesired operation.
P/N: 086L00XXXX-XXX