Cisco Cisco TelePresence MX700 Nota Di Rilascio
Introduction software version TC5.0.0
Cisco TelePresence System C-Series Software Release Notes
Page 11 of 36
Introduction software version TC5.0.0
This release note describes the features and capabilities included in the Cisco TelePresence System
C/MX/EX-Series codec software version TC5.0.0 released on 2
C/MX/EX-Series codec software version TC5.0.0 released on 2
nd
of December 2011.
Note: Please read the known limitations section if you use TMS to upgrade your system from any
release prior to TC4.0.0
release prior to TC4.0.0
With TC5.0.0 the C/EX/MX-Series supports provisioning and basic call functionality with
Cisco Unified Communications Manager (CUCM) version 8.6 and above. It also supports
Cisco Discovery Protocol (CDP) for easy deployment in CUCM environments. When
provisioning mode is set to CUCM the system will try to use Voice VLAN if available in your
network. When in other provisioning modes it will try to use Data VLAN.
Please
be aware that in future releases Voice VLAN will be set to ‘Auto’ as per Cisco
best practice. If you are using Cisco switches you need to prepare your network so
that network services (VCS, TMS, etc.) is reachable from your Voice VLAN.
that network services (VCS, TMS, etc.) is reachable from your Voice VLAN.
Hardware compatibility
The Cisco TelePresence endpoints are using a NAND flash memory for general storage and transfer
of data. The endpoints running TC software will be manufac tured with a new version of the flash
memory. Endpoints having the new version of the flash memory must run software TC4.2.1 or later.
Some previous TC software versions will be updated to support the new flash memory. Please check
the release note to find if the new version of the flash memory is supported. If your endpoint does not
have the CompatibilityLevel command it will not have the new flash memory installed.
The result returned when running the command will be either 0 or 1:
0 = The system does not have the new flash memory installed.
1 = The system has the new flash memory installed. If downgraded, it can only be downgraded to
previous TC software versions having support for the new version of the flash memory.
of data. The endpoints running TC software will be manufac tured with a new version of the flash
memory. Endpoints having the new version of the flash memory must run software TC4.2.1 or later.
Some previous TC software versions will be updated to support the new flash memory. Please check
the release note to find if the new version of the flash memory is supported. If your endpoint does not
have the CompatibilityLevel command it will not have the new flash memory installed.
The result returned when running the command will be either 0 or 1:
0 = The system does not have the new flash memory installed.
1 = The system has the new flash memory installed. If downgraded, it can only be downgraded to
previous TC software versions having support for the new version of the flash memory.
Example:
xstatus SystemUnit Hardware Module CompatibilityLevel
*s SystemUnit Hardware Module CompatibilityLevel: 0
** end
xstatus SystemUnit Hardware Module CompatibilityLevel
*s SystemUnit Hardware Module CompatibilityLevel: 0
** end