Cisco Cisco SG200-26P 26-port Gigabit PoE Smart Switch Manuale Di Manutenzione

Pagina di 195
Security
802.1X
Cisco Small Business SF200E Series Advanced Smart Switch
175
10
 
Quiet Period—Amount of time that the switch remains in the quiet state 
following a failed authentication exchange. During the quiet period, the 
switch does not accept or initiate authentication requests. Change the 
default value of this command only to adjust for unusual circumstances, such 
as unreliable links or specific behavioral problems with certain clients and 
authentication servers. To provide a faster response time to the user, enter a 
smaller number than the default (60 seconds). The range is 0–65535 
seconds.
Resending EAP—The amount of time that lapses before EAP requests are 
resent. The range is 1–65535 seconds and the default is 30 seconds.
Supplicant Timeout—The amount of time that lapses before EAP requests 
are resent to supplicants. Change the default value of this command (30 
seconds) only to adjust for unusual circumstances, such as unreliable links or 
specific behavioral problems with certain clients and authentication servers. 
To provide a faster response time to the user, enter a smaller number than the 
default. The range is 1–65535 seconds.
Server Timeout—The amount of time that lapses before the switch resends 
a request to the authentication server. The range is 1–65535 seconds and 
the default is 30 seconds.
Max EAP Requests—The preconfigured maximum number of times the 
switch can send an EAP request before restarting the authentication process 
if it does not receive a response. 
Termination Cause—The reason for termination.
STEP  4
Click Apply and then click Close. Your changes are saved to the Running 
Configuration.
Configuring Supplicant Port Authentication
Use the Supplicant Port Authentication page to configure port access control on 
ports that are configured in the supplicant role. To enable a port as an supplicant, 
se
.
To configure supplicant port authentication:
STEP 1
Click Security > 802.1X > Supplicant Port Authentication in the navigation 
window.
STEP  2
Select the port to configure and click Edit.