Problem:
SNTP synchronization error messages are not logged when an
incorrect MD5 key leads to the loss of synchronization. (CQ132636)
Solution:
There is no workaround for broadcast messages. For Unicast servers,
in the SNTP server table the status message will either say "In process" or "Down"
for those servers that have failed authentication.
for those servers that have failed authentication.
Problem:
The Cisco phone model 7960 (a legacy powered device) cannot
power-up when using a cross-over cable.
Solution:
Use straight cable instead.
Japanese language files and firmware version compatibility
guideline
guideline
Users will see a mismatch in the features between the English language and the
Japanese language when running certain combinations of firmware and language
files. Users will see new features added since version 1.1.1.6 in English instead of
Japanese in the GUI when running firmware version 1.1.2.0 and higher subject to
the following restriction:
Japanese language when running certain combinations of firmware and language
files. Users will see new features added since version 1.1.1.6 in English instead of
Japanese in the GUI when running firmware version 1.1.2.0 and higher subject to
the following restriction:
•
Japanese language files version 1.1.1.6 and older are forward compatible up
to Firmware version 1.1.2.0. For example: loading a version 1.1.1.6 language
file onto a device running firmware version 1.2.7.76 and up will fail.
to Firmware version 1.1.2.0. For example: loading a version 1.1.1.6 language
file onto a device running firmware version 1.2.7.76 and up will fail.
•
Japanese language files version 1.1.1.10 and newer are only compatible with
firmware version 1.2.7.76 and newer.