Limitations and Restrictions
The following caveats are acknowledged in release 1.3.0:
Problem:
When configuring egress shaping rates on port 1, and enable flow 
control on port2, the whole vlan port egress rates will be the same. Flow control 
uses the whole buffer management scheme. When one port is configured to FC 
ALL ports are applied by the new scheme. QoS function on other ports will be 
effected also. (CQ144583)
Solution:
When using QoS, disable the flow control function.
Problem:
You cannot configure IP address 192.168.1.0/24 subnet as an address 
pool, other subnets are allowed. (CQ145102)
Solution:
There is no workaround.
Problem:
The 
show environment command on a stack shows a temperature 
of 0 for all units if the switch without a sensor is the master in the stack. (CQ145525, 
CQ145542)
Solution:
There is no workaround.
Problem:
When managing a switch through the web-based interface, the loading 
time on some of the web pages can take a long time, approximately 3-10 seconds 
depending on the content in the tab. (CQ143850)
Solution:
Use the command line interface instead.
Problem:
When managing stacking switches through the web-based interface, 
the loading time on the following web pages is more than 10 seconds: (CQ143851)
Status and Statistics
Port Management
VLAN Management
Access Control
Quality of Service
Solution:
Use the command line interface instead.
Problem:
When the current master unit is already set to auto-numbering, 
reconfiguring it as 'auto' does not work. (CQ142567)
Solution: