Replaceable Components   
▀  Circuit Cards 
 
 
▄  ASR 5500 Installation Guide 
158 
   
Circuit Cards 
This section describes how to replace circuit cards in the ASR 5500 chassis. 
Determining Whether a Card has Failed 
The ASR 5500 has several ways to indicate an application card failure. The first indicator is that the Status LED on the 
System Status Card (SSC) turns red to indicate the failure of a chassis component. Another indicator is the Run/Fail 
LED on an application card is red or turns off if that card has a problem. 
If you see either of these indicators, you can determine the nature of the problem by using the CLI or checking the 
Simple Network Management Protocol (SNMP) traps that may have been generated. 
show card diag Command 
Execute the show card diag slot_# command from the CLI in Exec mode. slot_# is the chassis slot number in which the 
particular card that you wish to monitor is installed. The following is a sample output for this command to monitor the 
card in chassis slot 5: 
[local]asr5500# show card diag 5 
   
Card 5: 
Counters: 
    Successful Warm Boots : 0 
      (last at Friday July 29 13:45:58 us-eastern 2011) 
    Successful Cold Boots : 2 
      (last at Friday July 29 13:46:20 us-eastern 2011) 
    Total Boot Attempts   : 1 
    In Service Date       : Fri Jul 29 13:50:58 2011 
  Status: 
    IDEEPROM Magic Number : Good 
    Boot Mode             : Normal 
    Card Diagnostics      : Pass 
    Current Failure       : None 
    Last Failure          : None 
    Card Usable           : Yes 
  Current Environment: 
    Temp: DDR-C0D0        : 30.00 C (limit 100.00 C) 
    Temp: DDR-C0D1        : 30.00 C (limit 100.00 C) 
    Temp: DDR-C1D0        : 30.00 C (limit 100.00 C) 
    Temp: DDR-C1D1        : 30.00 C (limit 100.00 C) 
    Temp: DDR-C2D0        : 30.00 C (limit 100.00 C) 
    Temp: DDR-C2D1        : 30.00 C (limit 100.00 C) 
    Temp: CPU-N0C0        : 30.00 C (limit 101.00 C) 
    Temp: CPU-N0C1        : 30.00 C (limit 101.00 C) 
    Temp: CPU-N0C2        : 30.00 C (limit 101.00 C) 
    Temp: CPU-N0C3        : 30.00 C (limit 101.00 C) 
    Temp: CPU-N0C4        : 30.00 C (limit 101.00 C) 
    Temp: CPU-N0C5        : 30.00 C (limit 101.00 C)