CO Alarm Interface 
The Central Office (CO) Alarm interface on the SSC is a DB15 female connector that supports three low voltage, 
normally-closed/normally-open dry-contact relays. These Form C relays interface with an CO alarm monitor panel to 
trigger external audio and/or visual indicators. 
Three alarm levels are supported by the relays: 
 
Minor Alarm – This alarm is triggered when a high temperature is detected on a card, causing the fan tray to 
switch the fans to high speed. 
 
Major Alarm – This alarm is triggered when there is a: 
 
Hardware failure that causes the card to be placed in an off-line state 
 
PFU failure or removal from the chassis 
 
Failure of one or more fans on any of the upper or lower fan tray units 
 
Fan tray failure or any fan tray unit is removed from the chassis 
 
Critical Alarm – This alarm is triggered when a degradation in service is detected. For example, if the system is 
supporting a large number of subscribers and DPCs are removed, the amount of available CPU and memory 
resources available for use are reduced.