Cisco Cisco Packet Data Gateway (PDG) Guida Alla Risoluzione Dei Problemi
Global Configuration Mode Commands
▀ threshold asngw-r6-invalid-nai
▄ Cisco ASR 5000 Series Command Line Interface Reference
OL-22948-01
threshold asngw-r6-invalid-nai
Configures thresholds to generate alert/alarm for invalid Network Access Identifier (NAI) in R6 message.
Product
ASN-GW
Privilege
Security Administrator, Administrator
Syntax
Default: 0
The high threshold number of invalid NAIs in R6 messages that must be met or exceeded within the polling
interval to generate an alert or alarm.
The high threshold number of invalid NAIs in R6 messages that must be met or exceeded within the polling
interval to generate an alert or alarm.
can be configured to any integer value between 0 and 10000000. A value of 0 disables the
threshold.
Default: 0
The low threshold number of invalid NAIs in R6 messages that maintains a previously generated alarm
condition. If the number of denials falls beneath the low threshold within the polling interval, a clear alarm
will be generated.
The low threshold number of invalid NAIs in R6 messages that maintains a previously generated alarm
condition. If the number of denials falls beneath the low threshold within the polling interval, a clear alarm
will be generated.
can be configured to any integer value between 0 and 10000000. A value of 0 disables the
threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Use this command to set threshold limits to generate alerts or alarms based on the number of invalid NAIs in
R6 messages that occurred during the specified polling interval. Invalid NAIs are counted for an MS that the
system is configured to communicate with or per system for all R6 messages.
Alerts or alarms are triggered for invalid NAIs based on the following rules:
R6 messages that occurred during the specified polling interval. Invalid NAIs are counted for an MS that the
system is configured to communicate with or per system for all R6 messages.
Alerts or alarms are triggered for invalid NAIs based on the following rules:
Enter condition: Actual number of failures ³ High Threshold
Clear condition: Actual number of failures < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
Refer to the
of the polling interval.
Refer to the
command to configure the polling interval and the
command to enable thresholding for this value.