Cisco Cisco Packet Data Gateway (PDG) Guida Alla Risoluzione Dei Problemi

Pagina di 5213
  Global Configuration Mode Commands 
threshold dcca-protocol-error  ▀   
Cisco ASR 5000 Series Command Line Interface Reference  ▄  
 
  OL-22947-02 
threshold dcca-protocol-error 
Configures the threshold for Diameter Credit Control Application (DCCA) protocol error from Diameter server. 
Product
 
ECS 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Disables the threshold for configured alarm and sets the 
 and 
 values to 0. 
Default: 0 
The high threshold number of protocol error received from Diameter server that must be met or exceeded 
within the polling interval to generate an alert or alarm. 
The number can be configured to any integer value between 0 and 1044000. 
Default: 0 
The low threshold number of protocol error received from Diameter server that maintains a previously 
generated alarm condition. If the number of errors falls beneath the low threshold within the polling interval, 
a clear alarm will be generated. 
The number can be configured to any integer value between 0 and 1044000. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage
 
In the event that the system receives the protocol errors from Diameter server, dcca-protocol-error is 
generated. 
DCCA protocol error threshold generates alerts or alarms based on the number of protocol error messages 
received from Diameter server during the specified polling interval. 
Alerts or alarms are triggered for DCCA protocol error based on the following rules: 
 
Enter condition: Actual number of DCCA protocol error ³ High Threshold 
 
Clear condition: Actual number of DCCA protocol errors < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval. 
Example