Cisco Cisco Packet Data Gateway (PDG) Guida Alla Risoluzione Dei Problemi

Pagina di 5213
  Global Configuration Mode Commands 
threshold subscriber active  ▀   
Cisco ASR 5000 Series Command Line Interface Reference  ▄  
 
  OL-22947-02 
threshold subscriber active 
Configures active subscriber thresholds for the system. 
Product
 
PDSN, GGSN, SGSN, HA 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Default: 0 
The high threshold number of active subscriber sessions facilitated by the system that must be met or 
exceeded within the polling interval to generate an alert or alarm. 
The number can be configured to any integer value between 0 and 100000. A value of 0 disables the 
threshold. 
Default: 0 
The low threshold number of active subscriber sessions facilitated by the system that maintains a previously 
generated alarm condition. If the number of sessions falls beneath the low threshold within the polling 
interval, a clear alarm will be generated. 
The number can be configured to any integer value between 0 and 100000. A value of 0 disables the 
threshold. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage
 
Active subscriber thresholds generate alerts or alarms based on the total number of active subscriber sessions 
facilitated by the system during the specified polling interval. 
Alerts or alarms are triggered for active subscriber totals based on the following rules: 
 
Enter condition: Actual total number of active subscriber sessions ³ High Threshold 
 
Clear condition: Actual total number of active subscriber sessions < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval. 
Refer to the 
 command to configure the polling interval and the 
 command to enable thresholding for this value. 
Example 
The following command configures an active subscriber high threshold count of 
 and a low threshold of 
 
for an system using the Alarm thresholding model: