Cisco Cisco Nexus 5010 Switch Manuale Tecnico

Pagina di 16
What is important to remember is that to bring up the interface properly, a couple of different
actions need to happen as depicted in this diagram. 
Enode is an end node, while FCF is the switch. 
In order to verify the steps from one of the devices, the fcoe_mgr (FCoE manager) facility can be
used. In this case it is vfc 105. 
bdsol-n5548-05# show platform software fcoe_mgr info interface vfc 105
vfc105(0x841e4c4), if_index: 0x1e000068, VFC RID vfc105
 FSM current state: FCOE_MGR_VFC_ST_PHY_UP
PSS Runtime Config:-
Type: 3
Bound IF: Po105
FCF Priority: 128 (Global)
Disable FKA: 0
PSS Runtime Data:-
IOD: 0x00000000, WWN: 20:68:00:2a:6a:28:68:7f
Created at: Sat Sep 27 22:45:05 2014
FC Admin State: up
Oper State: up, Reason: down
Eth IF Index: Po105
Port Vsan: 70
 Port Mode: F port
 Config Vsan: 70
 Oper Vsan: 70
 Solicits on vsan: 70
Isolated Vsan: