Cisco Cisco Nexus 5010 Switch Manuale Tecnico

Pagina di 16
bdsol-n5548-05 configuration to NetApp
interface Ethernet1/6
switchport mode trunk
switchport trunk allowed vlan 970,3380
spanning-tree port type edge trunk
channel-group 106 mode active
interface port-channel106
switchport mode trunk
switchport trunk allowed vlan 970,3380
vpc 106
bdsol-n5548-05 FCoE configuration to UCS
interface Ethernet1/6
switchport mode trunk
switchport trunk allowed vlan 970,3380
spanning-tree port type edge trunk
channel-group 106 mode active
interface port-channel106
switchport mode trunk
switchport trunk allowed vlan 970,3380
vpc 106
As mentioned in the introduction to this document, this configuration depicts a single link in port
channel between UCS and Nexus switches. It is used for reference only and can be extended to
additional links.
The previous configuration is reflected on bdsol-n5548-06. The only change is to use VSAN 80
instead of VSAN 70.
Peer Link Port Channel
In this configuration each side of the fabric has only one FCoE VLAN. Those VLANs are not to be
trunked between Nexus 5000s.
Dependent upon the configuration standards and best practices, this can be completed by:
No additional changes - since VLANs are not created on both Nexus 5000s they cannot be
trunked. Those VLANs will be seen under "Vlans Err-disabled on Trunk".
Remove VLANs from the trunk via the switchport trunk allowed vlan except command.
Explicitly mention which VLANs are allowed -do not mention the FCoE VLANs.
Add the VFCs to the VSAN Database
The newly configured VFCs are added to VSAN database.
bdsol-n5548-05
interface Ethernet1/6
switchport mode trunk
switchport trunk allowed vlan 970,3380
spanning-tree port type edge trunk
channel-group 106 mode active
interface port-channel106
switchport mode trunk
switchport trunk allowed vlan 970,3380