Cisco Cisco Nexus 5010 Switch Guida Alla Progettazione

Pagina di 119
 
 
© 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 16 of 119 
Figure 6.    UDLD Probe Intervals 
 
UDLD normal mode uses the default 15-second message interval, which is also compatible with ISSU. 
 […] 
Current bidirectional state: bidirectional 
Current operational state:  advertisement - Single neighbor detected 
Message interval: 15 
During an ISSU upgrade, the Cisco Nexus 5000 Series Switch negotiates a higher message interval with the UDLD 
peer, and sets it to 60 seconds: 
Neighbor echo 1 devices: TBM12162254 
Neighbor echo 1 port: Ethernet2/9 
Message interval: 60 
PortChannel on Cisco Nexus 5000 Series 
There are hardware differences between the Cisco Nexus 5500 platform and the other Cisco Nexus 5000 Series 
Switches because of the higher port density that the Cisco Nexus 5500 platform supports. On the Cisco Nexus 
5500 platform, every single port can be a PortChannel; this is true for the Cisco Nexus 5548P, 5548UP, and 
5596UP.