Cisco Cisco Nexus 5010 Switch Guida Alla Progettazione

Pagina di 119
 
 
© 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 47 of 119 
● 
Have the same duplex mode configured 
● 
Have the same Ethernet layer (switch port or no switch port) configured 
● 
Not be Switched Port Analyzer (SPAN) ports 
● 
Have the same storm control configured 
● 
Have the same flow control configured 
● 
Have common capabilities 
● 
Be switching ports (Layer 2) 
● 
Have the same port access VLAN 
● 
Have the same port native VLAN 
● 
Have the same port-allowed VLAN list 
vPC Consistency Checks 
Like regular PortChannels, vPCs are subject to consistency checks and compatibility checks. During a compatibility 
check, one vPC peer conveys configuration information to the other vPC peer to verify that vPC member ports can 
actually form a PortChannel. For example, if two ports that are going to join the channel carry a different set of 
VLANs, a misconfiguration occurs. 
Depending on the severity of the misconfiguration, vPC may either warn the user (Type 2 misconfiguration) or 
suspend the PortChannel (Type 1 misconfiguration). In the specific case of a VLAN mismatch, only the VLAN that 
differs between the vPC member ports will be suspended on all the vPCs. 
You can verify the consistency between vPC peers by using the command show vpc consistency-parameter
tc-nexus5k02# show vpc consistency-parameter 
Inconsistencies can be global or interface specific: 
● 
Global inconsistencies: Type 1 global inconsistencies affect all vPC member ports (but do not affect non-
vPC ports). 
● 
Interface-specific inconsistencies: Type 1 interface-specific inconsistencies affect only the interface itself. 
Examples of areas where Type 1 inconsistencies may occur include
● 
MST region definition (VLAN-to-instance mapping) 
● 
MTU value 
● 
Spanning-tree global settings (Bridge Assurance, loop guard, and root guard) 
● 
Configuration changes to the following (these affect only individual vPCs for all VLANs on the vPC): 
◦ 
PortChannel mode 
◦ 
Trunk mode 
◦ 
Spanning-tree interface settings 
Note:   Mismatched QoS definitions were originally Type 1 inconsistencies, but in newer releases they are Type 2 
inconsistencies. For the Cisco Nexus 5000 Series, starting from Cisco NX-OS 5.0(2)N1(1), QoS inconsistencies 
are categorized as Type 2, and so they do not bring down vPC member ports if the configurations differ between 
vPC peers.