Best Practices with Cisco Nexus 2000 Series Fabric Extenders 
In addition to the best practices already listed for the Cisco Nexus 5000 Series, when deploying the Cisco Nexus 
2000 Series, you should consider the design options listed here. 
Note that spanning tree and LACP are not running between the Cisco Nexus 5000 Series Switches and the Cisco 
Nexus 2000 Series Fabric Extenders, so the user does not need to configure these protocols between the Cisco 
Nexus 5000 Series and the Cisco Nexus 2000 Series devices. Fabric extender ports are host ports, and so they 
are configured for BPDU filtering and for PortFast. 
Additional best practices include the following: 
● 
Each fabric extender module should be assigned a unique number. This unique number enables the same 
fabric extender to be deployed in single-attached mode to one Cisco Nexus 5000 Series Switch only or in 
fabric extender vPC mode (that is, dual-connected to different Cisco Nexus 5000 Series Switches). 
● 
Fabric connectivity between the fabric extender and the parent Cisco Nexus 5000 Series Switch should 
consider buffering requirements and oversubscription ratios. The more fabric links there are, the more buffer 
space is available for N2H traffic and the less oversubscription for H2N traffic. 
● 
Use fabric extender preprovisioning as much as possible. 
● 
Single-attached servers should be connected to a fabric extender dual-homed when possible so that the 
failure of one Cisco Nexus 5000 Series Switch does not isolate the server. 
● 
Dual-connected servers that require PortChannels must be connected to fabric extenders single-homed or 
dual-homed with two or more ports in the PortChannel and half of the ports attached to each fabric 
extender. 
● 
Dual-homed servers connected to straight-through fabric extenders can be configured for active-standby or 
active-active transmit load balancing, and the fabric extender ports should be configured with the vpc 
orphan-ports suspend option (Figure 41). 
● 
FCoE is supported for both fabric extender straight-through and fabric extender active-active topologies, but 
the fabric extender straight-through topology provides more equal load distribution than does the fabric 
extender active-active topology on the fabric links. 
● 
When connecting a server with CNAs in a vPC topology, if you want to use FCoE you should connect only 
one 10 Gigabit link per fabric. This link is seen as part of a vPC for Ethernet traffic and as a separate SAN 
fabric link from a Fibre Channel perspective.