Peer Gateway                    : Enabled 
Dual-active excluded VLANs      : - 
Graceful Consistency Check      : Enabled 
 
vPC Peer-link status 
--------------------------------------------------------------------- 
id   Port   Status Active vlans     
--   ----   ------ -------------------------------------------------- 
1    Po10   up     1,3,10,50,60                                              
 
You may also want to verify that the configurations of the two Cisco Nexus switches are consistent: 
nexus5500-1# show vpc consistency-parameters global  
 
    Legend: 
        Type 1 : vPC will be suspended in case of mismatch 
 
Name                        Type  Local Value            Peer Value              
-------------               ----  ---------------------- ----------------------- 
QoS                         2     ([], [], [], [], [],   ([], [], [], [], [],   
                                  [])                    [])                    
Network QoS (MTU)           2     (1538, 0, 0, 0, 0, 0)  (1538, 0, 0, 0, 0, 0)  
Input Queuing (Bandwidth)   2     (100, 0, 0, 0, 0, 0)   (100, 0, 0, 0, 0, 0)   
Output Queuing (Bandwidth)  2     (100, 0, 0, 0, 0, 0)   (100, 0, 0, 0, 0, 0)   
STP Mode                    1     MST                    MST                    
STP Disabled                1     None                   None                   
STP MST Region Name         1     dc1                    dc1                    
STP MST Region Revision     1     3                      3                      
STP MST Region Instance to  1                                                   
 VLAN Mapping                                                                   
STP Loopguard               1     Disabled               Disabled               
STP Bridge Assurance        1     Enabled                Enabled                
STP Port Type, Edge         1     Normal, Disabled,      Normal, Disabled,      
BPDUFilter, Edge BPDUGuard        Disabled               Disabled               
STP MST Simulate PVST       1     Enabled                Enabled                
Allowed VLANs               -     1,3,10,50,60           1,3,10,50,60           
Local suspended VLANs       -     -                      -         
The following command is useful after you define the vPC member ports, to check for orphan ports: 
tc-nexus5k01# show vpc orphan-ports