Cisco Cisco Nexus 5010 Switch Guida Alla Progettazione

Pagina di 20
 
 
© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 15 of 20 
Shut Lan                    1     No                     No                     
Allowed VLANs               -     10-14,21-24,30,50-51,6 10-14,21-24,30,50-51,6 
If any of these parameters differ between vPC peers, the vPC does not forward traffic. 
Rapid PVST+ and vPC Best Practices 
When configuring Rapid PVST+ with vPC, follow these best practices: 
● 
Associate the root role on the aggregation layer as usual and it is preferred to match the vPC primary and 
secondary roles with root and secondary root. Remember that if a peer link fails, the vPC ports on the 
secondary switch are shut down, so make sure that the topology works regardless of which vPC peer is the 
operational secondary switch. 
● 
Two options are available for non-vPC VLANs to avoid the scenario in which the switch virtual interface 
(SVIs) for non-VPC VLANs are shut down if the peer link fails. You can place the non-vPC VLANs on a 
backup link that is independent of and parallel to the vPC peer link. In this case, make sure to clear the peer 
link from the non-vPC VLANs. Alternatively, you can use the command dual-active exclude interface-vlan 
to help ensure that non-vPC SVIs stay available. 
MST and vPC Best Practices 
When configuring MST with vPC, you should follow the same best practices as for Rapid PVST+. In addition, you 
should follow these practices: 
● 
Associate the root and secondary root role at the aggregation layer and it is preferred to match the vPC 
primary and secondary roles with root and secondary root. 
● 
You do not need to use more than one instance for vPC VLANs. 
● 
Make sure to configure regions during the deployment phase. 
● 
If you make changes to the VLAN-to-instance mapping when vPC is already configured, remember to make 
changes on both the primary and secondary vPC peers to avoid a Type-1 global inconsistency. 
● 
Use the dual-active exclude interface-vlan command to avoid isolating non-vPC VLAN traffic when the 
peer link is lost. 
EtherChannel Misconfiguration Guard 
A dispute mechanism was introduced for the Cisco Catalyst 6500 Series Switches in Cisco IOS
®
 Software Release 
12.2(18)SXF for MST and in Cisco IOS Software Release 12.2(33)SXI for Rapid-PVST+, prior to the introduction of 
vPC to deal with a scenario such as the one described here. 
If upstream switch1 and switch2 are not configured for vPC, but the downstream access switches (switch3 and 
switch 4) are configured with PortChannel mode on, then broadcast frames will loop back, causing duplicates as 
depicted in Figure 9. The misconfiguration guard takes down the PortChannel on the downstream switch to avoid 
this scenario. 
The misconfiguration guard detects this scenario by seeing BPDUs with different Bridge IDs that originate on both 
PortChannel links.