Cisco Cisco Packet Data Gateway (PDG)

Pagina di 361
  System Settings 
Configuring ASR 5500 Link Aggregation  ▀   
 
ASR 5500 System Administration Guide, StarOS Release 17  ▄  
 
   
73 
Important:
  The VPN can only bind the master port, and a VLAN can only be created on the master port. A 
failure message is generated if you attempt to bind to a link aggregation member port. 
Each system that participates in link aggregation has a unique system ID that consists of a two-byte priority (where the 
lowest number [0] has the highest priority) and a six-byte MAC address derived from the first port’s MAC address. The 
following command sets the system priority used to form the system ID. P is a hex in the range [0x0000..0xFFFF]. The 
default is 0x8000. 
   card slot# 
     link-aggregation system-priority P 
Ports in a system are assigned keys. The group number maps directly to the key, whereupon only ports with the same 
key can be aggregated. Ports on each side of the link use a different aggregation key. 
The system ID, port key and port ID of two peers form the Link Aggregation Group Identifier (LAGID). You can 
aggregate links having the same LAGID. Systems are often configured initially with each port in its own aggregation 
(requiring a separate key per port), or with all ports in the same aggregation (a single key for all ports). Negotiation via 
LACP would qualify the actual aggregation. 
Systems exchange information about system ID, port key and port ID with peers across the physical links using LACP. 
LACP packets are defined with the Slow Protocol format. Each system sends out its own (“actor”) information and its 
last received information about its peer (“partner”) over the physical link. 
Use the following commands to set the LACP parameters. LACP can run in active mode to send LACP packets 
periodically, or in passive mode, in which it only responds to LACP packets it receives. 
LACP can send packets at either a auto (30s) or fast (1s) rate. The defaults for this release are Active and Auto; see the 
sample configuration below: 
config 
  port ethernet slot#/port# 
     link-aggregation lacp { active | passive } [ rate { auto | fast } | timeout 
{ long | short } ]
 
Peers send out LACP packets when the state changes or if a difference is found from a received LACP packet about its 
own state. 
Corresponding ports on an MIO/UMIO redundant pair cannot be active at the same time. Redundant ports share the 
same MAC address, so after a failover is resolved, the original port rejoins the link aggregation group. 
Redundancy Options 
For L2 redundancy set the following option on the master port for use with the whole group: 
link-aggregation redundancy standard [hold-time sec ] [preferred slot { card_number 
none }
 
Standard redundancy treats all cards in the group as one group.