Cisco Cisco Packet Data Gateway (PDG)

Pagina di 361
  Management Settings 
ORBEM and the Web Element Manager  ▀   
 
ASR 5500 System Administration Guide, StarOS Release 17  ▄  
 
   
79 
 
If a firewall exists between the system and the Web Element Manager, open the SIOP port number and the TCP 
port number 15011. 
 
If the ORB Notification Service is enabled via the event-notif-service command, you can set filters to determine 
which events are to be sent. By default, the Service sends all error and higher level events, “info” level events 
for the ORBS facility, CLI command logs, and license change logs. Optionally, configure a filter by including 
the event-notif-service filter command. Enter this command for each filter you need to configure. 
Configuring IIOP Transport Parameters 
Use the following example to configure Internet Inter-ORB Protocol (IIOP) transport parameters that enable ORB-based 
management to be performed over the network: 
configure 
   orbem 
      iiop-transport 
      iiop-port iiop_port_number 
      event-notif-iiop-port iiop_notif_port 
      end 
Notes: 
 
If you are using the Secure Sockets Layer (SSL) option, do not enable the IIOP transport parameter. The WEM 
default process enforces SSL. 
 
You configure the ORBEM interface to use SSL by specifying a certificate and private key.