Cisco Cisco Packet Data Gateway (PDG)

Pagina di 453
  Troubleshooting 
Detecting Faulty Hardware  ▀   
 
ASR 5000 System Administration Guide, StarOS Release 18  ▄  
 
   
221 
Checking the LEDs on Ethernet Line Cards 
The ASR 5000 can be equipped with a variety of Ethernet line cards that support subscriber traffic. For detailed 
information about the types of line cards and their applications, refer to the ASR 5000 Installation Guide 
The following line cards are currently supported on the ASR 5000: 
 
Fast Ethernet Line Card (FELC and FLC2): half-height, 8-ports, 10/100Base-T interfaces 
 
Gigabit Ethernet Line Card (GELC and GLC2): half-height, 1-ports, SFP interface 
 
Quad GigE Line Card (QGLC): half-height, 4-ports, SFP interfaces 
 
10  Gigabit Line Card (XGLC): full-height, 1-port, SFP+ interfaces 
Each of the Ethernet cards listed above is equipped with status LEDs as listed below: 
 
Run/Fail 
 
Active 
 
Standby 
In addition to the LEDs listed above, each network interface is equipped with the Link and Activity LEDs. 
The possible states for all LEDs on these Ethernet line cards are described below. 
Ethernet Line Card Run/Fail LED States 
The Run/Fail LEDs on the Ethernet line cards indicate the overall status of the cards. These LEDs should be green for 
normal operation. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 29.  Ethernet Line Card Run/Fail LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Card powered with no 
errors detected.
 
None needed.
 
Red
 
Card powered with 
error(s) detected.
 
Errors were detected during the Power On Self Tests (POSTs). It is likely that the errors 
were logged to the command line interface during the boot process.
 
Refer to Monitoring the System for information on determining the status of system 
hardware components.
 
None
 
Card is not receiving 
power.
 
Verify that the POWER LEDs on the PFUs are green. If they are not, refer to 
for troubleshooting information.
 
Verify that the power source is supplying ample voltage and current to the chassis.
 
Verify that the card is properly installed per the instructions in the ASR 5000 Installation 
Guide
.
 
If all of the above suggestions have been verified, it is possible that the line card is not 
functional. Please contact your service representative.