Cisco Cisco Packet Data Gateway (PDG)
Context Configuration Mode Commands N-R
▀ radius accounting rp
▄ Command Line Interface Reference, StarOS Release 18
2710
radius accounting rp
This command configures the current context’s RADIUS accounting R-P originated call options.
Product
PDSN
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration > Context Configuration
configure > context context_name
Entering the above command sequence results in the following prompt:
[context_name]host_name(config-ctx)#
Syntax
radius accounting rp { handoff-stop { immediate | wait-active-stop } | tod minute hour |
trigger-event { active-handoff | active-start-param-change | active-stop } | trigger-
policy { airlink-usage [ counter-rollover ] | custom [ active-handoff | active-start-
param-change | active-stop ] | standard } | trigger-stop-start }
trigger-event { active-handoff | active-start-param-change | active-stop } | trigger-
policy { airlink-usage [ counter-rollover ] | custom [ active-handoff | active-start-
param-change | active-stop ] | standard } | trigger-stop-start }
no radius accounting rp { tod minute hour | trigger-event { active-handoff | active-
start-param-change | active-stop } | trigger-stop-start }
start-param-change | active-stop } | trigger-stop-start }
default radius accounting rp { handoff-stop | trigger-policy }
no
Removes earlier configuration for the specified keyword.
default
Configures this command with the default settings.
handoff-stop { immediate | wait-active-stop }
Specifies the behavior of generating accounting STOP when handoff occurs.
immediate
: Indicates that accounting STOP should be generated immediately on handoff, i.e. not to
wait active-stop from the old PCF.
wait-active-stop
:Indicates that accounting STOP is generated only when active-stop received from
the old PCF when handoff occurs.
Default:
wait-active-stop
tod minute hour
Specifies the time of day a RADIUS event is to be generated for accounting. Up to four different times of the
day may be specified through separate commands.
day may be specified through separate commands.
minute
must be an integer from 0 through 59.
hour
must be an integer from 0 through 23.