Cisco Cisco Packet Data Gateway (PDG)

Pagina di 8770
Exec Mode Commands (D-S)   
▀  hd raid 
 
 
▄  Command Line Interface Reference, StarOS Release 16 
3996 
   
insert local1
 | 
remote1
 
On the ASR 5000, inserts the specified disk to the running RAID causing it to recover from degraded mode. 
local1:
 specifies the primary SMC is to be inserted into the RAID. 
remote1:
 specifies the backup SMC is 
to be inserted into the RAID. 
insert hd_num
 
On the ASR 5500, inserts the specified FSC disk array into the running RAID causing it to recover from 
degraded mode. 
hd_num
 specifies the RAID is to be established on the FSC in slot numbers 13 through 18 (hd13, hd14, ... 
hd18).  
insert { | local1 | local2 }
 
On VPC, inserts the specified vHD into the running RAID causing it to recover from degraded mode. 
overwrite local1
 | 
remote1
 
On the ASR 5000, overwrites the specified disk and adds it to the current running RAID to construct a fully 
mirrored array. 
local1
 specifies the primary SMC is to be added to the current RAID. 
remote1
 specifies the backup SMC 
is to be added to the current RAID. 
overwrite hd_num
 
On the ASR 5500, overwrites the specified FSC disk array and adds it to the current running RAID to 
construct a fully mirrored array. 
hd_num
 specifies the RAID is to be established on the FSC in slot numbers 13 through 18 (hd13, hd14, ... 
hd18).  
overwrite { | local1 | local2 }
 
On VPC, overwrites the specified vHD and adds it to the current running RAID to construct a fully mirrored 
array. 
remove
 
local1
 | 
remote1
 
On the ASR 5000, removes the specified disk from the running RAID causing it to run in degraded mode or 
to fail. 
local1:
 specifies the primary SMC is to be removed from the RAID. 
remote1:
 specifies the backup SMC 
is to be removed from the RAID. 
remove
 
hd_num
 
On the ASR 5500, removes the specified FSC disk array from the running RAID causing it to run in degraded 
mode or to fail. 
hd_num
 specifies the RAID is to be established on the FSC in slot numbers 13 through 18 (hd13, hd14, ... 
hd18).  
remove
 
{ | local1 | local2 }
 
On the VPC, removes the specified vHD from the running RAID causing it to run in degraded mode or to 
fail.