Cisco Cisco Packet Data Gateway (PDG)

Pagina di 8770
Global Configuration Mode Commands (threshold ppp - url-blacklisting)   
▀  threshold ppp-setup-fail-rate 
 
 
▄  Command Line Interface Reference, StarOS Release 16 
5796 
   
threshold ppp-setup-fail-rate 
Configures alarm or alert thresholds for the percentage of point-to-point protocol (PPP) setup failures. 
Product
 
PDSN 
GGSN 
Privilege
 
Security Administrator, Administrator 
Mode
 
Exec > Global Configuration 
configure
 
Entering the above command sequence results in the following prompt: 
[local]host_name(config)# 
Syntax
 
threshold ppp-setup-fail-rate high_thresh [ clear low_thresh ] 
high_thresh
 
Default: 0 
Specifies the high threshold rate percentage for PPP setup failures experienced by the system that must be 
met or exceeded within the polling interval to generate an alert or alarm. 
high_thresh
 is an integer from 0 through 100. A value of 0 disables the threshold. 
clear 
low_thresh
 
Default: 0 
Specifies the low threshold rate percentage for PPP setup failures experienced by the system that maintains a 
previously generated alarm condition. If the number of setup failures falls beneath the low threshold within 
the polling interval, a clear alarm will be generated. 
low_thresh
 is an integer from 0 through 100. A value of 0 disables the threshold. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage 
PPP setup failure rate thresholds generate alerts or alarms based on the rate of call setup failures experienced 
by the system during the specified polling interval. The failure rate is the percentage of failures as determined 
by number of PPP setup failures divided by the total number of PPP sessions initiated. 
Alerts or alarms are triggered for PPP setup failure rates based on the following rules: 
 
Enter condition: Actual number of call setup failures is greater than or equal to the high threshold. 
 
Clear condition: Actual number of call setup failures is less than the low threshold. 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval.