Cisco Cisco Packet Data Gateway (PDG)

Pagina di 465
S-GW CDR Field Descriptions   
▀  CDR Fields 
 
 
▄  GTPP Interface Administration and Reference, StarOS Release 18 
418 
   
SGW IPv6 Binary Address 
This field is the serving control plane S-GW IPv6 address on the S5 interface.
 
Format 
Octet string
 
Length 
16 bytes
 
SGW Change 
This field is present only in the SGW-CDR to indicate that this is the first record after an S-GW change. In this case, it is set 
to TRUE (“FF”)
 
Format 
Boolean
 
Length 
1 byte
 
Start Time 
This field contains the time when the IP-CAN session starts at the S-GW/P-GW, available in the CDR for the first bearer in an 
IP-CAN session.
 
The timestamp is determined based on the internal timer which has an accuracy of 10ms. Depending on the 
configured mechanism this is translated into the timestamp which only shows the full seconds.
 
The format is shown below.
 
TimeStamp ::= OCTET STRING (SIZE(6))
 
The contents of this field are a compact form of the UTC Time format containing local time plus an offset to 
universal time. Binary coded decimal encoding is employed for the digits to reduce the storage and transmission 
overhead
 
    -- e.g. YYMMDDhhmmssShhmm
 
    -- where
 
    -- YY    =    Year 00 to 99        BCD encoded
 
    -- MM   =    Month 01 to 12     BCD encoded
 
    -- DD    =    Day 01 to 31         BCD encoded
 
    -- hh      =    hour 00 to 23        BCD encoded
 
    -- mm    =    minute 00 to 59     BCD encoded
 
    -- ss       =    second 00 to 59     BCD encoded
 
    -- S        =    Sign 0 = “+”, “-”    ASCII encoded
 
    -- hh      =    hour 00 to 23          BCD encoded
 
    -- mm    =    minute 00 to 59      BCD encoded
 
Format 
BCD encoded octet string