  GTPP Accounting Overview 
Triggers for Generation of Charging Records  ▀   
 
GTPP Interface Administration and Reference, StarOS Release 18  ▄  
 
   
43 
time, or number of events) per rating group or combination of the rating group and service id within the same IP-CAN 
bearer, on encountering that trigger condition. 
Table 13.  Triggers for PGW-CDR Charging Information Addition 
Trigger Conditions 
Description/Behavior 
IP-CAN bearer 
modification 
A change of IP-CAN bearer conditions (QoS change, SGSN/S-GW change, PLMN Id change, RAT 
change, user location change) results in a set of “List of Service Data” containers, such as all active 
service data flow containers, being added to the CDR. 
Tariff Time Change 
On reaching the Tariff Time Change, a set of “List of Service Data” containers, such as all active 
service data flow containers, is added to the CDR. 
DCCA Failure-
Handling procedure 
triggering 
When the Diameter Credit-Control-Failure-Handling mechanism is triggered a “List of Service Data”, 
such as all active service data flow containers, is added to the CDR. 
The causes are only relevant due to simultaneous usage of an active DCCA session. 
Service data flow report  For independent online and offline charging, a “List of Service Data” container for the service data flow 
is added at: 
 
expiry of time limit 
 
expiry of volume limit 
 
expiry of unit limit 
 
termination of service data flow 
For tight interworking of online and offline charging, a “List of Service Data” container for the service 
data flow is added when: 
 
time threshold reached 
 
volume threshold reached 
 
unit threshold reached 
 
time quota exhausted 
 
volume quota exhausted 
 
unit quota exhausted 
 
expiry of quota validity timer 
 
termination of service data flow – re-authorization request by OCS. 
 
S-CDR Triggers 
The SGSN will use the Charging Characteristics to determine whether to activate or deactivate CDR generation. The 
Charging Characteristics are also used to set the coherent chargeable event conditions (e.g. time/volume limits that 
trigger CDR generation or information addition). Multiple Charging Characteristics "profiles" may be configured on the 
SGSN to allow different sets of trigger values. 
Triggers for S-CDR Closure 
The following events trigger closure and sending of a partial S-CDR: