Cisco Cisco Packet Data Gateway (PDG)

Pagina di 642
MME Changes in Release 16   
▀  MME Enhancements for 16.0 
 
 
▄  Release Change Reference, StarOS Release 16 
294 
   
CSCul61714 - Support for statistics to distinguish between CLI or HSS initiated 
Trace 
Performance Indicator Changes 
show session trace subcsriber subscriber network-element mme trace-ref
 
The following field has been introduced to the output of this command to indicate the source of the session trace, either 
HSS-initiated (Signaling) or CLI-initated (Management). 
 
 MME: Trace Type: Management or Signaling 
CSCun28592 - S6a Feature List AVP is hardcoded in MME 
Feature Changes 
Feature-List AVP Value in Messages Sent to HSS
 
Previous Behavior:  The MME always sent the Feature-List AVP value as 67110415 (0x400060F) as specified in TS 
29.272 (prior to Version 10). 
New Behavior:  To comply with TS 29.272 Version 10 which changed the position of the T-ADS bit, the value sent in 
the Feature-List AVP is now configurable using the existing 
diameter update-dictionary-avps
 command in the 
HSS Peer Service Configuration Mode. 
If this command is configured using the 
3gpp-r9
 keyword, 0x400060f is sent.  
If this command is configured using the 
3gpp-r10
 keyword, 0x800060f is sent. 
CSCzn16621, CSCzn16622 - MME needs to support non-3gpp-to-LTE handover 
Feature Changes 
Unoptimized Non-3GPP Handover Support
 
This feature provides MME support for Non-3GPP to EUTRAN and EUTRAN to Non-3GPP un-optimized handovers. 
These include the LTE-eHRPD handover scenarios in sections 8.2.1.1 and 8.2.1.2, and 8.2.2 and 8.2.3 of 3GPP TS 
23.402-910. 
No configuration is required to enable this functionality on the MME. 
Note: 
 
PDN Connectivity request should contain Request Type as HANDOVER. 
 
P-GW is selected only through HSS-provided P-GW address or FQDN (MIP6-Info), with P-GW allocation type 
as static always. 
 
In the case of multiple PDN connectivity during handover from non-3gpp access to EUTRAN, the ESM PDN 
connectivity message from UE is transported via S1AP Uplink NAS transport. All other such PDN 
connectivity requests shall be rejected.