Cisco Cisco Packet Data Gateway (PDG)
SaMOG Gateway Offline Charging
▀ SaMOG CDR Formats
▄ SaMOG Administration Guide, StarOS Release 17
70
Field
Category Description
Node ID
OM
Name of the recording entity.
This field contains an identifier string for the node that generates the CDR. On the SaMOG
Gateway, the NodeID field is a printable string of the ndddSTRING format.
This field contains an identifier string for the node that generates the CDR. On the SaMOG
Gateway, the NodeID field is a printable string of the ndddSTRING format.
Local Record
Sequence Number
Sequence Number
OM
Consecutive record number created by the node. The number is allocated sequentially
including all CDR types.
For each Node ID, the number with range 1 through 4294967295 is allocated sequentially for
each CDR.
including all CDR types.
For each Node ID, the number with range 1 through 4294967295 is allocated sequentially for
each CDR.
APN Selection
Mode
Mode
OM
An index indicating how the APN was selected.
Set to 0:MS or network provided APN, subscriber verified.
Set to 0:MS or network provided APN, subscriber verified.
Served MSISDN
OM
The primary MSISDN of the subscriber.
Received in the Subscription-ID AVP in DEA.
Received in the Subscription-ID AVP in DEA.
Charging
Characteristics
Characteristics
M
The Charging Characteristics applied to the IP CAN bearer.
Will be received from AAA in DEA 3GPP-Charging-Characteristics.
Will be received from AAA in DEA 3GPP-Charging-Characteristics.
Charging
Characteristics
Selection Mode
Characteristics
Selection Mode
OM
Holds information about how Charging Characteristics were selected.
Values:
Values:
ServingNodeSupplied
homeDefault
roamingDefault
visitingDefault
P-GW Address
Used
Used
OC
P-GW IP address for the Control Plane
The P-GW address received from the AVP MIP6-Agent-Info in DEA. If this value is not
received, MRME performs DNS.
The P-GW address received from the AVP MIP6-Agent-Info in DEA. If this value is not
received, MRME performs DNS.
Serving Node
PLMN Identifier
PLMN Identifier
OC
Serving node PLMN Identifier (MCC and MNC) used during this record, if available.
Received in NAI in Radius Access request.
Received in NAI in Radius Access request.
RAT Type
OC
Radio Access Technology (RAT) type currently used by the Mobile Station, when available.
Set to WLAN.
Set to WLAN.
Start Time
OC
Time when User IP-CAN session starts, available in the CDR for the first bearer in an IP-CAN
session.
Set by the SaMOG Gateway.
session.
Set by the SaMOG Gateway.
Stop Time
OC
Time when User IP-CAN session is terminated, available in the CDR for the last bearer in an
IP-CAN session.
Set by the SaMOG Gateway.
IP-CAN session.
Set by the SaMOG Gateway.
SaMOG SGSN CDR Format
The following table lists the SGSN CDR fields present in the available GTPP dictionary used by the SaMOG Gateway.