Cisco Cisco Packet Data Gateway (PDG)

Pagina di 242
SecGW Service Creation   
▀  Prerequisites 
 
 
▄  SecGW Administration Guide, StarOS Release 18 
28 
   
Prerequisites 
This section describes the requirements that must be met prior to configuring the SecGW. 
VPC-VSM Installation 
VPC-VSM must be running in a virtual machine on a VSM CPU within the ASR 9000 chassis. This guide does not 
describe the installation process. Refer to other ASR 9000 documentation for detailed installation instructions. 
The StarOS command line interface (CLI) for each VPC-VSM instance should be accessible via a remote access 
management port that is defined during the installation process. Refer to the VPC-VSM System Administration Guide for 
additional information on setting primary and secondary IP addresses for StarOS management ports. Alternatively, the 
StarOS CLI can be accessed via a hypervisor vConsole port. 
For intrachassis and interchassis IPSec High Availability (HA) deployments, VPC-VSM must be installed on VSMs in 
the ASR 9000 chassis. StarOS Interchassis Session Recovery (ICSR) must also be enabled. Refer to the VPC-VSM 
System Administration Guide
 for ICSR installation and configuration information. For additional configuration 
requirements, see the High Availability for RRI section in the Reverse Route Injection chapter of this guide. 
Refer to ASR 9000 documentation for additional information on HA active-standby configuration. 
Network Interfaces 
You will need to know the addressing information for all external interfaces to StarOS. The list of addresses is included 
but not limited to: 
 
WSG service (endpoints, access groups) 
 
VLANs 
 
SNMP 
 
DHCP