Cisco Cisco Packet Data Interworking Function (PDIF) Dépliant

Pagina di 931
Starent Chassis Traps   
▀  MIB Textual Conventions 
 
 
▄  Cisco ASR 5x00 Series SNMP MIB Reference 
434 
   
Object ID
 
enterprise.8164.2.6 
Description
 
A voltage regulation failure has been detected this card. 
Probable Cause: Problem with incoming power; failure of power filters; hardware issue with card. Note that this is an 
extremely abnormal condition.  
Action to be Taken: Verify that the power supplied to the chassis is operating correctly; use the CLI/Web Element 
Manager to check the state of the chassis power filters; replace the card. 
Clear Condition: This is not a recoverable error except via restarting the card, so the condition is only cleared via a 
starCardUp or starCardActive notification. 
Objects
 
starSlotNum 
starCardType 
Object 
starCardRemoved
 
Object ID
 
enterprise.8164.2.7 
Description
 
A card has been removed from the chassis. 
Probable Cause: An operator has physically unlocked and removed a card from the chassis. 
Action to be Taken: No action is required. If the card removal was unplanned, the admin logs can identify the time 
when the card was initially unlocked. 
Objects
 
starSlotNum 
starCardType 
Object 
starCardInserted
 
Object ID
 
enterprise.8164.2.8 
Description
 
A card has been inserted into the chassis. 
Objects
 
starSlotNum 
starCardType 
Object 
starCardBootFailed