Cisco Cisco ONS 15454 M6 Multiservice Transport Platform (MSTP)

Pagina di 19
The USB-WRITE-FAIL alarm is raised on the node controller when a bulk performance monitoring parameter query is run on a large
multi-shelf configuration.
Critical Bug Fixes in Release 9.6.0.7
The following critical issues have been resolved in Release 9.6.0.7:
• The TNC/TSC cards reset with the Backup Memory Failure (BKUPMEMP) alarm when all the sockets in the node are leaked.
• After upgrading the node from earlier releases to release 9.6.0.5, the OSC Termination failed alarm is raised.
• Exhaustion of the temporary pipes that are needed for the communication between TNC card and line-card software tasks is
seen.
Critical Bug Fixes in Release 9.6.0.5
The following critical issues have been resolved in Release 9.6.0.5:
• The release addresses the control card resets and USB sync/write related alarms for several scenarios.
• The OSC link on the standby TNC/TNC-E card raises an EOC alarm periodically.
• The Secure Shell access might not work after upgrading the ONS 15454 software package or after a control card reset.
• The OPT-EDFA-24 card remains in APR mode when the optical channel is switched on after a fiber cut or during circuit
provisioning which might cause traffic recovery or bring up issues.
• The control card resets when loopback is set as Terminal on the trunk port of 100G-LC-C card in MXP-10x10G operating mode.
• The Provisionable Patchcords (PPCs) are occasionally deleted in CTC after the ENE node is reset.
• The TL1 session occasionally locks up on ONS 15600 and ONS 15454 nodes. The new TL1 sessions cannot be opened.
• Some client and trunk ports of the OTU2-XP and AR-XP cards display invalid Rx and Tx power values (-40 dBm) resulting in
invalid power threshold crossing alarm.
• During a software upgrade in a multi-shelf setup, the line cards in the subtended shelf reboot that might result in traffic loss.
• OSPF LSDB shows invalid link metric values which causes sub-optimal routing to NEs.
Critical Bug Fixes in Release 9.6.0.4
The following critical issues have been resolved in Release 9.6.0.4:
• On the ONS 15454 M6 shelf, when the 100G-LC-C card is provisioned on a slot that is below the CFP-LC card slot position,
traffic does not flow through the ports of the CFP-LC card.
• If a port of a GE_XP, GE_XPE, 10GE_XP, or 10GE_XPE card is not part of the Link Aggregation Group (LAG), then Link
Aggregation Control Protocol (LACP) BPDU packets are dropped at the ingress of the port, even when the port is configured
to tunnel BPDU packets.
• The nodes in a multishelf configuration of more than 20 shelves, each carrying the maximum permissible number of 40G and
100G muxponder cards, cannot be managed because the node controllers (TCC3 and TNC) reboot frequently.
• When the client signal is of type ISC3, traffic does not flow between two AR_MXP cards.
4