Cisco PowerKEY CableCARD Module 801 Riferimenti tecnici
Audience
This quick reference sheet is for staging area personnel who stage new, RMA,
or field-return SSC (Separable Security Host with CableCARD
or field-return SSC (Separable Security Host with CableCARD
TM
module)
Explorer
®
DHCTs that have either one or three LEDs.
Scope
This document only addresses staging for SSC DHCTs. For information on
staging non-SSC DHCTs, refer to the Explorer Digital Home Communications
Terminal Staging Guide (part number 734375).
staging non-SSC DHCTs, refer to the Explorer Digital Home Communications
Terminal Staging Guide (part number 734375).
Document Version
This is the first revision of this document.
Permission to Copy
You may photocopy this document for use in your staging area.
Additional Documentation
For more detailed information about staging and other concepts discussed in
this document, read the following publications:
this document, read the following publications:
•
DBDS Utilities Version 6.3 Installation Instructions and User Guide (part
number 4031374)
•
Downloading New Client Application Platform Installation Instructions (part
number 4003052)
•
Explorer Digital Home Communications Terminal Staging Guide (part number
734375)
•
M-Card and S-Card Diagnostic Screens on a TV Host: A Reference Guide
(part number 4015203)
•
RNG and 8550 Diagnostic Screens Application Guide (part number 4010384)
•
Separable Security Host Staging Guide (part number 736107)
•
Separable Security Host Staging Guide for System Release 4.3 and Later
Operation & Maintenance Guide (part number 4024836)
•
Troubleshooting Power LED SSC Set-Tops with Single- and Triple- LEDs
(part number 4021198)
•
Troubleshooting Scientific Atlanta’s Separable Security Set-Tops (part
number 4019359)
•
Understanding Diagnostic Screens for the Explorer DHCTs Application Guide
(part number 749244)
Staging New and RMA SSC DHCTs
1. Check with your DNCS operator and billing system operator to verify that the
EMM data for the SSC DHCTs you are preparing to stage has been properly
installed.
installed.
2. Scan the DHCTs into the billing system using the appropriate procedures
authorized by your billing system provider.
Important
: Ensure that the billing system operator does
not
send billing
transactions to the DHCT at this time.
3. Unpack the DHCTs and place them onto the staging rack.
4. Connect the CABLE IN port to the RF signal.
5. Connect the DHCTs to AC power. The DHCT downloads the OS and ResApp
4. Connect the CABLE IN port to the RF signal.
5. Connect the DHCTs to AC power. The DHCT downloads the OS and ResApp
software from the DNCS. One of the following actions occurs:
•
One LED
: The POWER LED blinks twice, pauses, and repeats during
this
download.
•
Three LEDs
: The LEDs rotate to the right.
Important
: To view the staging progress on a TV monitor, you must power
on the DHCT.
6. After a few minutes, the set-top reboots.
7. After the reboot, the paired CableCARD module begins to download the
7. After the reboot, the paired CableCARD module begins to download the
software from the DNCS. The POWER LED blinks twice, pauses, and repeats
during the download.
during the download.
Important
: You will only see this download pattern if you are using software
version EXP2.1.0.0501 or later. Older versions of software will not display
any indication during the CableCARD module download. If you are using
an older version of code, you must connect a TV monitor to the DHCT to
monitor the CableCARD module download.
any indication during the CableCARD module download. If you are using
an older version of code, you must connect a TV monitor to the DHCT to
monitor the CableCARD module download.
8. Wait for the DHCTs to reboot and to indicate that the CableCARD module
download is complete. The DHCT will be in a power off state. Power on the
DHCT. The POWER LED will either blink eight times, pause, then repeat (brick
mode indicator) or blink four times, pause and repeat only once (normal
operation indicator).
DHCT. The POWER LED will either blink eight times, pause, then repeat (brick
mode indicator) or blink four times, pause and repeat only once (normal
operation indicator).
9. Power the DHCT on and send a “hit” from the billing system to the DNCS to
place the set-tops in service with at least one package. The DHCT will be
in a power off state. Power on the DHCT. The POWER LED will either blink
eight times, pause, then repeat (brick mode indicator) or blink four times,
pause and repeat only once (normal operation indicator).
in a power off state. Power on the DHCT. The POWER LED will either blink
eight times, pause, then repeat (brick mode indicator) or blink four times,
pause and repeat only once (normal operation indicator).
10. At this time, binding* should occur. Are you using manual binding?
•
If
yes
, follow the procedures in
Manual Binding
in the Separable Security
Host Staging Guide (part number 736107) or Separable Security Host Staging
Guide for System Release 4.3 and Later Operation & Maintenance Guide
(part number 4024836).
Guide for System Release 4.3 and Later Operation & Maintenance Guide
(part number 4024836).
•
If
no
, you are using either combo binding or autobinding. The binding process
should occur without intervention.
11. Verify authorized and high-value copy-protected channels.
12. Does your business process require inventory DHCTs to be authorized for
12. Does your business process require inventory DHCTs to be authorized for
service?
•
If
yes
, go to step 13.
•
If
no
, downgrade (disable) the DHCTs in accordance to your site process,
wait for the POWER LED to blink eight times, pause, then repeat (brick mode
indicator) or for the loss of secure services, and then go to step 13.
indicator) or for the loss of secure services, and then go to step 13.
13. Disconnect the DHCTs and prepare them for shipment by placing them back
in the original shipping container.
Note
: Some sites reverse steps 12 and 13 to let installers see services
during installation before having the DHCT receive a hit with the subscriber’s
contracted services. If your site does this, the DHCT will only display services
if it is installed within the EMM timeout period. After the timeout period, the
DHCT will need to receive a hit before it can display secure services.
contracted services. If your site does this, the DHCT will only display services
if it is installed within the EMM timeout period. After the timeout period, the
DHCT will need to receive a hit before it can display secure services.
Viewing Diagnostic Screens on the SSC DHCTs (SARA Only)
1. On the remote control, press and hold the
PAUSE
button until the POWER
LED blinks, then press the
PAGE +
button.
Note
: You can also view the diagnostic screens by following these steps:
a Press and hold the
POWER
button until the POWER LED on the front
panel blinks, then release the
POWER
button.
b While the LED continues to blink, press the
POWER
button a second time.
(Do not hold the
POWER
button the second time.) The LED should blink
quickly.
2. To page up and page down within the diagnostic screens, press
PAGE +/PAGE UP/NEXT +
or
PAGE -/PAGE DOWN/NEXT -
, based on the
type of remote control you are using.
3. To exit the diagnostic screens, press the
EXIT
button on the remote control.
Staging Area Quick Reference Sheet for SSC DHCTs
with One or Three LEDs
with One or Three LEDs