Chapter 5    Web GUI Setup and Monitoring 
 
 
 
166 
OL-29015-01 
5  Choose Enable from the TS/ONID Check drop-down if you want to restrict the 
incoming transport stream to the transport ID and transport original network ID 
listed below. If the incoming stream does not match the specified transport 
stream, the CAM will not decrypt. The default is Disable. 
6  If you set the TS/ONID Check to Enable, you must define the Transport ID and 
Original Network ID. If the incoming stream does not match the specified IDs 
here, the CAM will not decrypt. You can enter a value in a range from 0 to 65535. 
7  From the CAM TS Handling drop-down list, choose EntireTS to use the CAM to 
decrypt the entire transport stream, or choose ServicesOnly to use the CAM to 
decrypt only the PIDs being used by the active services. 
8  Click Apply
 
Setting up the Common Interface Program Description 
1  
From the CI Slot drop-down lists, choose the CAM slot to use for decryption. If 
you set the CI Slot to AUTO for PE1, the software automatically assigns the slot 
capable of decrypting the stream.  
Note: If CI Slot is set to AUTO, the Decryption Mode must be set to ON
Choose TOP to use the top CAM slot for decryption or choose BOTTOM to use 
the bottom CAM slot for decryption. 
2  The Decryption Mode determines whether to decrypt the channel or to specify 
the specific components to decrypt (ON, OFF, Comp). Choose ON (default) to 
decrypt the entire program entry. Choose Comp to decrypt specific components, 
as specified in the CI Component Setup list below. 
Note: If the CI Slot is set to Auto for PE1, then Decryption Mode can only be set 
to ON
3  Click Apply.  
 
Configuring the CI Component 
The CI Component Setup area allows you to insert and maintain customized 
records: