Setting up Cueing Parameters 
1  From the user interface of the D9824, choose Audio & Video > Cueing. The 
Cueing page is displayed. 
 
2  From the Cueing Mode drop-down list, choose whether cueing output should be 
DTMF tones or trigger pins. 
Tones are standard Dual-Tone Multi-Frequency (DTMF) tones. The tones are 
generated at the Cue Tone/Relay output on the rear panel of the receiver. 
Trigger refers to open-collector pins which can be generated at the Cue 
Tone/Relay output on the rear panel of the receiver. 
3  If Trigger is selected as the Cueing Mode, choose the pin polarity from the 
Trigger Polarity drop-down list. Choose High for the pins to act as open or 
floating collectors on an active cueing signal and as ground on an inactive signal. 
Choose Low for the pins to act as ground on an active cueing signal and as open 
or floating collectors on an inactive signal. 
4  If the Cueing Mode was set to Tone, enter the number of consecutive tone 
sequences to be generated in the Cueing Tone Repeat Count field. Values 
greater than 1 are provided when a scenario demands repetition to ensure that 
the ad insertion equipment receives the signal. You can enter 1, 2, or 3. The 
default is 3. 
5  If the Cueing Mode is set to Tone, enter the tone duration for each tone in the 
Tone Duration field, in milliseconds, in the range from 0 to 80. The default is 40. 
6  If the Cueing Mode is set to Tone, enter the silence duration of each silence 
between tones in the Silence Duration field, in milliseconds. The duration is in 