Cisco Cisco D9804 Multiple Transport Receiver Guida All'Installazione

Pagina di 220
 
Chapter 5    Setup and Monitoring 
 
 
 
116 
78-4042990-01 Rev B 
 
Setting up Telemetry Control 
Proceed as follows to set up the Telemetry Control: 
1  From the user interface of the D9804 MTR, click the Setup tab and then the 
Telemetry icon from the sub-page. 
 
2  Select the Telemetry output (Enabled or Disabled). The Telemetry Output is the 
state of the RS-232 data output. 
3  Type the Repetition Rate (Sec), the transmission interval for the RS-232 data. 
Enter a value in the range of 1 to 60 seconds, in 1 second intervals. The default is 
30 seconds. It is highly recommended to keep the value at default. 
4  Select the Baud Rate, a RS-232 asynchronous data at rates up to 38.4 kbps. The 
selections are: 300, 600, 1200, 2400, 4800, 9600, 19200 and 38400 bps. The default is 
9600 bps. 
If the repetition interval is less than the minimum required for a particular baud 
rate, the configuration will be rejected. 
Baud Rate 
Minimum Repetition Interval 
300 
30 
600 
20 
1200 
15 
2400 
10 
4800 
9600 
19200 
38400 
5  Select the Parity (Even, Odd, or None) for the RS-232 Telemetry interface on the 
rear panel. 
6  Select the Data Bits (7 or 8) for the RS-232 Telemetry interface on the rear panel.