Cisco Cisco D9804 Multiple Transport Receiver Guida All'Installazione
Chapter 5 Setup and Monitoring
116
78-4042990-01 Rev B
Setting up Telemetry Control
Proceed as follows to set up the Telemetry Control:
1 From the user interface of the D9804 MTR, click the Setup tab and then the
1 From the user interface of the D9804 MTR, click the Setup tab and then the
Telemetry icon from the sub-page.
2 Select the Telemetry output (Enabled or Disabled). The Telemetry Output is the
state of the RS-232 data output.
3 Type the Repetition Rate (Sec), the transmission interval for the RS-232 data.
Enter a value in the range of 1 to 60 seconds, in 1 second intervals. The default is
30 seconds. It is highly recommended to keep the value at default.
30 seconds. It is highly recommended to keep the value at default.
4 Select the Baud Rate, a RS-232 asynchronous data at rates up to 38.4 kbps. The
selections are: 300, 600, 1200, 2400, 4800, 9600, 19200 and 38400 bps. The default is
9600 bps.
If the repetition interval is less than the minimum required for a particular baud
rate, the configuration will be rejected.
9600 bps.
If the repetition interval is less than the minimum required for a particular baud
rate, the configuration will be rejected.
Baud Rate
Minimum Repetition Interval
300
30
600
20
1200
15
2400
10
4800
9
9600
7
19200
5
38400
1
5 Select the Parity (Even, Odd, or None) for the RS-232 Telemetry interface on the
rear panel.