Converting a Cisco CDE250 TV CDS System to an 
Internet Streamer CDS System (v2.0 BIOS)
Revised: October 2012 OL-26165-02
To convert a Cisco CDE250 TV CDS system with version 2.0 BIOS (a non-hyperthreading configurable 
BIOS) to an Internet Streamer CDS system, perform the following steps:
Note
This procedure only applies if your CDE250 TV system has BIOS revision older than 2.0c. If your BIOS 
is revision 2.0c or later, then you only need to do Step 11.
Step 1
Connect a VGA monitor and keyboard to the TV CDS system.
Step 2
Restart the TV CDS system.
Step 3
When the AMIBIOS American Megatrends, Inc. screen is displayed, enter the BIOS Setup Menu by 
pressing <Delete> several times.