Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Guida All'Installazione
Mounting the Node
Mounting the Node
The following procedures detail how to install the GainMaker node housing on a
strand (aerial) or in a pedestal.
To Install the Node on a Strand (Aerial)
Complete the following steps to install the node on a strand (aerial). The housing
does not need to be opened for strand installation.
Important: The minimum strand diameter should be 5/16 inch.
Important: The minimum strand diameter should be 5/16 inch.
CAUTION:
Be aware of the size and weight of the Node while strand mounting.
Ensure that the strand can safely support the weight of the Node.
1 Loosen the strand clamp bolts.
2 Lift the housing into proper position on the strand.
3 Slip the strand clamps over the strand and finger-tighten the clamp bolts. This
2 Lift the housing into proper position on the strand.
3 Slip the strand clamps over the strand and finger-tighten the clamp bolts. This
allows additional movement of the housing as needed.
4 Move the housing as needed to install the coaxial cable and connectors. See the
following diagrams for examples.
Signal Flow from Left to Right
Signal Flow from Left to Right
Signal Flow from Right to Left
Note: If supplying power to the node through the main input port, a power
inserter must be installed to terminate the RF signal.
OL-30326-02
29