Cisco Headend System Release 2.7 Guida Alla Progettazione
Chapter 2 Monitoring SDV Alarms
56
4002915 Rev B
SDV Program Management Alarms
SDV Server Trap 400 (190 Hex)
Alarm Summary:
Program Removed with Viewers
Description:
This alarm occurs when the SDV server removes a program from the edge device to
free up bandwidth for a higher-priority program.
free up bandwidth for a higher-priority program.
Severity:
Minor
Service Impact:
Important: If this alarm occurs frequently, it may be an indicator of insufficient
bandwidth allocation for the service group.
bandwidth allocation for the service group.
Check and Correct:
Possible Cause
Check and Correct Instructions
Program priority or business rule triggered
action.
action.
This alarm occurs when one of the following
instances occurs:
instances occurs:
When the DNCS demands the removal
of programs from the SDV server
of programs from the SDV server
When the SDV server detects no recent
subscriber activity and bandwidth is
required to satisfy a new program
request (for example, bandwidth
reclamation)
subscriber activity and bandwidth is
required to satisfy a new program
request (for example, bandwidth
reclamation)
If this alarm occurs frequently, consider the
following options to add additional
bandwidth to the affected service group:
following options to add additional
bandwidth to the affected service group:
Check the bandwidth allocated for the
affected service group and verify that
the maximum bandwidth is allocated.
affected service group and verify that
the maximum bandwidth is allocated.
Add additional QAMs to your system.
Contact the representative that handles
your account for more information.
Contact the representative that handles
your account for more information.