Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Guida All'Installazione

Pagina di 282
 
Chapter 1    General Information 
 
 
 
12 
OL-29643-02 
Module Description
Status 
Monitor/ Local 
Control 
Module 
(SM/LCM) 
The local control module monitors the input optical power of 
up to four receivers and four transmitters, plus AC power entry 
and power supply voltage rails. It also provides local reverse 
path wink and shutdown capabilities through the PC-based 
GS7000 ViewPort software. It can be upgraded to a status 
monitor which provides node monitoring and control capability 
at the cable plant's headend. This module is not required for 
normal operation of the node. In a hub node application the 
SM/LCM also monitors and controls the operation of the 
EDFAs and optical switches. 
Power Supply 
The power supply module has multiple output voltages of 
+24.5, +8.5, -6.0, and +5.5 V DC. A second power supply can be 
installed in the node for redundancy or load sharing. 
The GS7000 Node can be set up in the following powering 
configurations: 
 
two power supplies powered by different AC sources 
 
two power supplies using the same AC source 
 
a single supply using a single AC source 
Fiber 
Management 
Tray and Track 
The fiber management system secures and protects the optical 
fiber inside the node housing. 
Optical 
Interface Board 
The Optical Interface Board (OIB) provides all interconnections 
between the modules in the housing lid of the GS7000 Node. 
Each module in the lid plugs directly into the OIB through a 
connector header or row of sockets. Input attenuator pads are 
provided on the OIB for each optical receiver in the housing lid. 
Output attenuator pads are provided on the OIB for each 
optical transmitter in the housing lid. 
Two Optical Interface Boards are available, a standard 
eight-position OIB and an optional six-position OIB which is 
primarily used in digital return applications.