Chapter 2    Theory of Operation 
 
 
 
34 
OL-29643-02 
The thermal circuit on the RF amplifier module is designed to compensate for the RF 
forward path thermal movement of the entire node RF station. This includes the 
forward path amplifier module circuitry, RF cables, and optical interface board 
circuitry. It does not include the thermal movement of the optical receivers. 
Forward Configuration Module 
The forward configuration module determines the forward path topology in the RF 
amplifier module and the GS7000 Node. The output signals from one to four optical 
receivers enter the forward configuration module where they are combined and or 
directed to the two or four independent forward paths in the RF amplifier module. 
Forward path segmentation and/or redundancy are set by plugging the appropriate 
forward configuration module into the RF amplifier module. The forward 
configuration module is a plug-in, field accessible module. See Forward 
Configuration Module
 (on page 36) for more information. 
Forward Band Linear Equalizer Module 
The forward band linear equalizer module sets the overall forward path tilt of the RF 
amplifier module and the GS7000 Node. The 4-way segmentable launch amplifier is 
shipped with four 15.0 dB linear equalizers installed in the RF amplifier module. 
One equalizer is installed in each of the amplifier modules four forward paths. The 
2-way segmentable launch amplifier is shipped with two 7.5 dB linear equalizers 
installed in the RF amplifier module. One equalizer is installed in each of the 
amplifier modules two forward paths. This sets the nodes forward path tilt to 14.5 
dB linear. Forward band linear equalizer modules of other values are available. This 
allows the nodes forward path tilt to be adjusted as needed. The forward band linear 
equalizer module is a plug-in, field accessible module. See the equalizer charts in 
Appendix A - Technical Information
Node Signal Director Jumper/Splitter Module 
Node signal director jumper/splitter modules are present on the center output ports 
on either end of the RF amplifier module. The orientation of these modules 
determines where the RF amplifiers center output port signals are directed. The 
node signal director jumper allows the center output port signals to be routed to 
either the amplifiers primary center output port or to its auxiliary corner output port. 
The node signal director splitter module splits the center output port signals equally 
between the primary and auxiliary output ports. The node signal director 
jumper/splitter module is a plug-in, field accessible module. 
Auxiliary Reverse Injection Director Module 
Auxiliary reverse injection director modules are present on the auxiliary corner 
output ports on either end of the RF amplifier module. The orientation of these 
modules determine if the nodes auxiliary output ports are configured to be primary 
or split node output ports, or local reverse injection ports. The auxiliary reverse 
injection director module is a plug-in module. It is accessible only after the RF